Page 77
Set Up Arming
To configure different arming and disarming options, from the Setup menu, press the 5 (ARM) key.
Entry Delay
The Entry Delay is the time, in seconds, that you have to disarm the alarm system after entering your home. The Entry Delay
only applies to the entry/exit zone (e.g. your entry doors). If you (or someone else) come in through a window, there will be no
entry delay and the alarm will sound immediately.
When you come in through a door on an entry/exit zone, the other zones are delayed too. This allows you to get to your phone or
console to turn off the security system, even if you have to go through a room protected by a motion detector.
Some doors (a back door or garage door) may be configured as a Double or Quadruple Entry Delay. If so, that door has two
times or four times the entry delay shown on the display.
ENTRY DELAY: 30
30-60 SECONDS
↓
The default Entry Delay is 30 seconds. You may change it from 30 to 60 seconds.
Exit Delay
The Exit Delay is the time, in seconds, that you have to leave your house when you turn on the system. When arming the system
in Day, Night, Away, or Vacation modes, the system will wait this amount of time before arming.
EXIT DELAY: 60
45-180 SECONDS ↕
The default Exit Delay is 60 seconds. You may change it from 45 to 180 seconds.
Exit Time Restart
When Exit Time Restart is set to Yes, the Exit Delay will restart if the same exit zone is violated twice within the original exit
delay. For example, after arming the system if you open the front door to leave, close the front door behind you, and then reenter
through the front door while the exit delay is still in effect, the exit delay will be restarted. This is designed to give you additional
time to exit without causing an alarm. The exit time will only be restarted once within a given arming period.
To configure Exit Time Restart, from the Set Up menu, press the 5 (ARM) key.
EXIT TIME RESTART: 1
0=NO 1=YES ↕
The default setting for Exit Time Restart is “Yes”.
Unvacated Premises
When Unvacated Premises is set to Yes, if the alarm is armed in Away or Vacation mode and no exit zone is violated during the
exit delay (i.e. the premises was not vacated), the system will automatically arm to Day mode at the expiration of the exit delay.
To configure Unvacated Premises, from the Set Up menu, press the 5 (ARM) key.
UNVACATED PREM: 1
0=NO 1=YES ↕
The default setting for Unvacated Premises is “Yes”.
Kommentare zu diesen Handbüchern