PC/VDT PROGRAMMING - BATCH ENROLL DATA CHIPS
9-230
System 2 Installation / Programming Manual
Note: Although the display states the Option is Not Active, the output(s) have been assigned to the selected schedule.
However, it will not activate until the Second Door has been turned ON. Proceed to Option #13 to turn this Option ON.
The unit assigns this output to the user codes for those customers who wish to upgrade a one-door system (2003) to a two-
door system (2016) in the future, but do not wish to re-program the outputs.
Additional Outputs
When a valid Data Chip is entered, the door relay for that Port may be activated. In addition to
this activation, you might want other outputs to be activated to sound an alarm, trip a dialer, or
send some other signal. There are four such outputs from which to choose. The Program Aux
Outputs section of this manual details the physical properties of the outputs. Any, all, or none of
these outputs may be triggered by a user, if the Second Door is activated.
Refer to Option #13 to purchase this option.
The VDT will display the instructions:
Assign These Output(s)
to User ID
1=Aux Relay 1
2=Aux Relay 2
3=Voltage Output 1
4=Voltage Output 2
0=None
Outputs [----]
At the Outputs [ - - - - ] prompt, enter the desired output(s), if any, then press
ENTER.
Example: If you select Outputs 1 and 3, each time this group enters their code the door will
open and Aux Relay 1 and Voltage Output 1 will activate... provided you have installed a two-
door System 2 (2016).
If you select any of these Outputs and you have not activated the Second Door the VDT will
display:
Option Not Active!
Install in Option 13
Press Any Key